SICOM3028GPT is a intelligent modular platform which is an All-in-One solution integrating IEEE1588v2, Sync-E, full gigabit, and both layer 2 & Layer 3 availability specifically designed to operate reliably in electrically harsh and climatically demanding utility substation and industrial environments. SICOM3028GPT supports up to 28 gigabit fiber/copper ports, meets the IEC61850 and IEEE1613 standards. SICOM3028GPT is a 19-inch 1U rack mountable device and supports one 1U slot and six 0.5U slots which offers the maximum flexibility for easy expansion.SICOM3028GPT supports IEEE1588v2 and synchronous Ethernet protocol with hardware time stamping and supports the BC, P2P TC, and E2E TC clock modes, it reaches a timing precision of 100 ns. It supports Power Profile and Telecom Profile, and supports many modules for time synchronous like HSR/PRP, TimeServer, GPS, IRIG-B and TMS-trigger etc. SICOM3028GPT supports many Layer 2 software features such as port, VLAN, multicast, QoS, fast redundant ring and Layer 3 functions such as VRRP, RIP, OSFP, IGMP and PIM. It supports Console, Telnet, Web management and network management software based on SNMP. By expanding the serial server module, the product can provide up to 24 RS232/422/485 serial ports. At present, the product is widely used at the intelligent substation and many other industrial communication systems.
Flexible modular design for easy expansion, supports max 28 gigabit fiber/copper ports.
Supports DT-Ring ,DRP, MSTP and VRRP for network redundancy.
Supports Layer 3 routing protocols such as RIP and OSPF.
Supports IEEE1588v2 and the synchronization precision reaches ±100 ns, with SW based PTP 1588 and optional HW based PTP 1588.
Supports ITU-T.G.8261/G.8262 synchronous Ethernet and the synchronization precision reaches ±50 ns.
Supports HSR/PRP module, TimeServer module, GPS module, IRIG-B module, TMS-trigger module, Serial server module, LED module.
Supports Hot-Swappable Power Supplies.
Supports IEC61850 MMS management.
Supports cable test.
Complies with IEC61850-3 and IEEE1613.
KEMA, CE, FCC, EN50155/EN50121, UL61010, NEMA-TS2.
Software functions | |
Switching function | Supports VLAN and PVLAN. Supports GVRP Supports port aggregation and LACP. Supports flow control. Supports broadcast storm suppression. Supports QinQ Supports MAC address management |
Redundancy protocol | Supports DHP and DRP and the recovery time<20 ms. Supports DT-Ring, DT-Ring+, and DT-VLAN and the recovery time<50 ms. Supports RSTP/MSTP and compatible with STP. |
Multicast protocol | Supports IGMP snooping. Supports GMRP. Supports static multicast. Supports GOOSE over IP tunnel (receiver)(Web interface doesn't support) |
L3 function (part of sub-models support) | Supports ARP proxy Supports RIPv1/v2. Supports OSFPv2. Supports static routing. Supports VRRP. Supports IGMP Supports PIM SM,PIMDM Supports GOOSE over IP tunnel (sender) (Web interface doesn't support) |
Security | Supports IEEE 802.1x. Supports HTTPS/SSL. Supports SSH. Supports SFTP client. Supports RADIUS. Supports TACACS+. Supports user grading. Supports MAC address binding. Supports port isolate. Supports security IP for Web/Telnet/SSH/SNMP service |
Service quality management | Supports ACL Supports 802.1p(CoS),DSCP Supports priority mapping. Supports SP and WRR queuing. |
Management and maintenance | Supports Console, Telnet, and Web(HTTP or HTTPs) management methods. Supports SNMPv1/v2c/v3 and can managed by Kyvision. Supports IEC61850 MMS management. Supports TFTP server/client. Supports FTP server/client. Supports file transfer and software update over FTP and TFTP. Supports the IP/MAC address conflict alarm, power failure alarm, power alarm, temperature alarm, port linkdown alarm, port traffic alarm, CRC and packet lose alarm, CPU alarm, memory alarm, Sfp port rx power alarm, transceiver alarm and ring alarm (Web interface doesn’t support address conflict alarm. Sfp port rx power alarm, transceiver alarm need supported by hardware). Supports port mirroring. Supports cable test. Supports DDM. Supports loop detection Supports CRC protection Supports Syslog. Supports RMON Supports LLDP. Supports Link-check. Supports NTP and SNTP. Supports RTC. Supports timezone and DST. |
IP address management | Supports Bootp. Supports DHCP server/client. Supports Up to 16 different IP addresses and VLAN for system management |
Time synchronization (part of sub-models support) | Supports PTPv2 (IEEE1588-2008). Supports Power profile (C37.238). Supports Telecom profile (in special version). Supports synchronous Ethernet (ITU-T.G.8261/G.8262). Supports TMS function. |
Product Specifications | |
Standard | IEEE 802.3i (10Base-T) IEEE 802.3u (100Base-T) IEEE 802.3ab (1000Base-T) IEEE 802.3ad (port aggregation) IEEE 802.3z (1000Base-SX/LX) IEEE 802.3x (flow control) IEEE 802.1p (priority) IEEE 802.1Q (VLAN) IEEE 802.1w (RSTP) IEEE 802.1s (MSTP) IEEE 802.1x IEEE1588-2008 (PTPv2) ITU-T.G.8261/G.8262 (synchronous Ethernet) |
Switch properties | Priority queue: 8 Number of VLANs: 4K VLAN ID: 1–4093 Number of multicast groups: 256 Routing table: 8K (L2 chassis do not involve) MAC table: 16K Packet buffer: 12Mbit (SICOM3028GPT-L3F/L3FT/L3G/L3GT), 8Mbit (SICOM3028GPT-L2F/L2FT/L2G/L2GT) Packet forwarding rate: 41.7Mpps (SICOM3028GPT-L2G/L2GT/L3G/L3GT), 9.5Mpps (SICOM3028GPT-L2F/L2FT/L3F/L3FT) Switching delay: < 10 μs Jumbo Frame Size: 10 KB |
Interface | Console port: Mini USB, RJ45 Alarm contact: 3-pin 5.08mm-spacing plug-in terminal block, 250 VAC/220 VDC Max, 2 A Max, 10A@1s, 60 W Max Slots for module: 1U: 1, 0.5U: 6 |
LED | LED on front panel Alarm LED: Alarm Running LED: Run Ring Role LED: Ring Synchronization finish LED: Lock Power LED: PWR1, PWR2 Port LED: Link/ACT Port speed LED: Speed LED on rear panel Port LED: Link/ACT Port speed LED: Speed |
Power Requirements | Power input: 24VDC (18-36 VDC) 48VDC (36-72 VDC) 100-240VAC,50/60Hz;110-220VDC (85-264VAC/77-300VDC) Power terminal: 5-pin 5.08 mm-spacing plug-in terminal block Power consumption: < 40 W Overload protection: Support Reverse connection protection: Support Redundancy protection: Support Hot Swappable: Support |
Physical Characteristics | Housing: Metal Cooling: Natural cooling, fanless Protection Class: IP40 Dimensions(W×H×D): 482.6 mm × 44 mm × 359.7 mm Weight: < 10 Kg Mounting: 19 inch 1U rack mounting |
Environmental limits | Operating temperature: -40°C to +85°C Storage temperature: -40°C to +85°C Ambient Relative Humidity: 5% to 95% (non-condensing) |
Quality assurance | MTBF: 360000h (SICOM3028GPT-L2F/L2G) 359000h (SICOM3028GPT-L2FT/L2GT) 371000h (SICOM3028GPT-L3F/L3G) 368000h (SICOM3028GPT-L3FT/L3GT) Warranty: 5 years |
Approvals | KEMA: Models with power supply of HV:100-240VAC,50/60Hz;110-220VDC CE: All models FCC: All models EN50155/50121: Models with power supply of HV:100-240VAC,50/60Hz;110-220VDC NEMA-TS2: Models with power supply of HV:100-240VAC,50/60Hz;110-220VDC UL61010 IEC 62368-1, EN 62368-1 IEC 62439-3 |
Industry standard | EMI FCC CFR47 Part 15, EN55022/CISPR22, Class A EMS IEC61000-4-2(ESD) ±8 kV (contact), ±15 kV(air) IEC61000-4-3(RS) 10 V/m (80 MHz-2 GHz) IEC61000-4-4(EFT) Power Port: ±4 kV; Data Port: ±2 kV IEC61000-4-5(Surge) Power Port: ±2 kV/DM, ±4 kV/CM; Data Port: ±2 kV IEC61000-4-6(CS) 3 V (10 kHz-150 kHz); 10 V (150 kHz-80 MHz) IEC61000-4-8 (power frequency magnetic field) 100 A/m(cont.), 1000 A/m(1s-3s) IEC61000-4-9 (pulsed magnetic field) 1000 A/m IEC61000-4-10 (damped oscillation) 100 A/m IEC61000-4-12 (oscillatory wave) 2.5 kV/CM, 1 kV/DM IEC61000-4-16 (common mode conduction) 30 V(cont.), 300 V(1s) Machinery IEC60068-2-6 (vibration) IEC60068-2-27 (shock) IEC60068-2-32 (free fall) Climatic environmental IEC60068-2-1 Cold test IEC60068-2-2 Dry heat test IEC60068-2-14 Change of temperature test IEC60068-2-30 Damp heat cyclic test IEC60068-2-78 Damp heat steady state test |
Hot-Swappable:
Product selection table
Sub-model | Ethernet Ports | L2 function | L3 function | Time synchronization |
SICOM3028GPT-L2GT | Up to 28 Gigabit ports | ● | ● | |
SICOM3028GPT-L2G | Up to 28 Gigabit ports | ● | ||
SICOM3028GPT-L2FT | Up to 4 Gigabit ports and 24 Fast Ethernet ports | ● | ● | |
SICOM3028GPT-L2F | Up to 4 Gigabit ports and 24 Fast Ethernet ports | ● | ||
SICOM3028GPT-L3GT | Up to 28 Gigabit ports | ● | ● | ● |
SICOM3028GPT-L3G | Up to 28 Gigabit ports | ● | ● | |
SICOM3028GPT-L3FT | Up to 4 Gigabit ports and 24 Fast Ethernet ports | ● | ● | ● |
SICOM3028GPT-L3F | Up to 4 Gigabit ports and 24 Fast Ethernet ports | ● | ● |
Ordering Information
Recommended model
Product Model | SICOM3028GPT-SM-PS1-PS2 |
Code definition | Code selection |
SM: Sub-model | L2GT-MB: SICOM3028GPT 28G ports L2 Chassis with time synchronization L2G-MB: SICOM3028GPT 28G ports L2 Chassis L2FT-MB: SICOM3028GPT 24+4G ports L2 Chassis with time synchronization L2F-MB: SICOM3028GPT 24+4G ports L2 Chassis L3GT-MB: SICOM3028GPT 28G ports L3 Chassis with time synchronization L3G-MB: SICOM3028GPT 28G ports L3 Chassis L3FT-MB: SICOM3028GPT 24+4G ports L3 Chassis with time synchronization L3F-MB: SICOM3028GPT 24+4G ports L3 Chassis |
PS1: power input 1 | HV=100-240VAC,50/60Hz;110-220VDC(85-264VAC/77-300VDC) L1=48VDC(36-72VDC) L3=24VDC(18-36VDC) |
PS2: power input 2 | HV=100-240VAC,50/60Hz;110-220VDC(85-264VAC/77-300VDC) L1=48VDC(36-72VDC) L3=24VDC(18-36VDC) NA: no redundant power supply |
Hot-Swappable Chassis | SICOM3028GPT-SM |
SM: Sub-model | L2GT-MB: SICOM3028GPT 28G ports L2 Chassis with time synchronization L2G-MB: SICOM3028GPT 28G ports L2 Chassis L2FT-MB: SICOM3028GPT 24+4G ports L2 Chassis with time synchronization L2F-MB: SICOM3028GPT 24+4G ports L2 Chassis L3GT-MB: SICOM3028GPT 28G ports L3 Chassis with time synchronization L3G-MB: SICOM3028GPT 28G ports L3 Chassis L3FT-MB: SICOM3028GPT 24+4G ports L3 Chassis with time synchronization L3F-MB: SICOM3028GPT 24+4G ports L3 Chassis |
Hot-Swappable Power Module | SM6.6-Power-PS |
PS: power input |
HV=100-240VAC,50/60Hz;110-220VDC(85-264VAC/77-300VDC), 1U
L1=48VDC(36-72VDC), 1U
L3=24VDC(18-36VDC), 1U |
Slot 1: | SM6.6-Ports-1U |
Ports: | 4GX=4x1000Base-X, 10/100/1000Base-T(X) SFP port,1U 4GX-DDM=4x1000Base-X, 10/100/1000Base-T(X) SFP port, DDM, 1U 4GE=4x10/100/1000Base-T(X) RJ45 port, 1U 2GX2GE=2x1000Base-X, 10/100/1000Base-T(X) SFP port; 2x10/100/1000Base-T(X) RJ45 port, 1U |
Slot2-Slot7: | SM6.6-Ports-Connector-0.5U |
Ports: | 4GX=4x1000Base-X, 100Base-FX, 10/100/1000Base-T(X) SFP port, 0.5U 4GX-DDM=4x1000Base-X, 100Base-FX, 10/100/1000Base-T(X) SFP port, DDM, 0.5U 4SFP-DDM=4x100Base-FX SFP port, DDM, 0.5U 4GE=4x10/100/1000Base-T(X) RJ45 port, 0.5U 2GX2GE=2x1000Base-X, 100Base-FX, 10/100/1000Base-T(X) SFP port; 2x10/100/1000Base-T(X) RJ45 port, 0.5U 2GX2S=2x1000Base-X, 100Base-FX, 10/100/1000Base-T(X) SFP port; 2x100Base-FX, single-mode fiber port, 0.5U 2GX2M=2x1000Base-X, 100Base-FX, 10/100/1000Base-T(X) SFP port; 2x100Base-FX, multi-mode fiber port, 0.5U 4S=4x100Base-FX, single-mode fiber port, 0.5U 4M=4x100Base-FX, multi-mode fiber port, 0.5U 2S2T=2x100Base-FX, single-mode fiber port; 2x10/100Base-T(X) RJ45 port, 0.5U 2M2T=2x100Base-FX, multi-mode fiber port; 2x10/100Base-T(X) RJ45 port, 0.5U 4T=4x10/100Base-T(X) RJ45 port, 0.5U |
Connector: 100M fiber port specifications | SC05=SC connector, multi-mode, 1310nm, 5km ST05=ST connector, multi-mode, 1310nm, 5km FC05=FC connector, multi-mode, 1310nm, 5km SC40=SC connector, single-mode, 1310nm, 40km ST40=ST connector, single-mode, 1310nm, 40km FC40=FC connector, single-mode, 1310nm, 40km SC60=SC connector, single-mode, 1310nm, 60km SC80=SC connector, single-mode, 1550nm, 80km |
Slot2-Slot7: | Module |
SM6.6-HSR/PRP-GE-0.5U = Redbox module, 2x100/1000Base-T RJ45 port |
|
Slot7: | Module |
SM6.6-LED-0.5U = LED module, Alarm LED, Running LED, Power LED, Port LED |
Module adaptive table
SICOM3028GPT | ||||||||
L2GT | L2G | L2FT | L2F | L3GT | L3G | L3FT | L3F | |
SM6.6-LED-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-HSR/PRP-GE-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-HSR/PRP-GX-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-PTP-BO-0.5U | √ | √ | √ | √ | ||||
SM6.6-GPS-OI-0.5U | √ | √ | √ | √ | ||||
SM6.6-TMS-Trigger-1U | √ | √ | √ | √ | ||||
SM6.6-TimeServer-ST850-1U | √ | √ | √ | √ | ||||
SM6.6-TimeServer-ST850-1U-S1 | √ | √ | √ | √ | ||||
SM6.6-TimeServer-ST850-1U-S2 | √ | √ | √ | √ | ||||
SM6.6-TimeServer-ST850-1U-S3 | √ | √ | √ | √ | ||||
SM6.6-TimeServer-ST850-1U-S4 | √ | √ | √ | √ | ||||
SM6.6-TimeServer-ST1310-1U | √ | √ | √ | √ | ||||
SM6.6-TimeServer-ST1310-1U-S1 | √ | √ | √ | √ | ||||
SM6.6-TimeServer-ST1310-1U-S2 | √ | √ | √ | √ | ||||
SM6.6-TimeServer-ST1310-1U-S3 | √ | √ | √ | √ | ||||
SM6.6-TimeServer-ST1310-1U-S4 | √ | √ | √ | √ | ||||
SM6.6-4D-232/422/485-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-4D-A-4RS232/422/485-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-4GX-1U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-4GX-DDM-1U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-4GE-1U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-2GX2GE-1U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-4GX-0.5U | √ | √ | √ | √ | ||||
SM6.6-4GX-DDM-0.5U | √ | √ | √ | √ | ||||
SM6.6-4SFP-DDM-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-4GE-0.5U | √ | √ | √ | √ | ||||
SM6.6-2GX2GE-0.5U | √ | √ | √ | √ | ||||
SM6.6-2GX2M-ST05-0.5U | √ | √ | √ | √ | ||||
SM6.6-2GX2M-SC05-0.5U | √ | √ | √ | √ | ||||
SM6.6-2GX2M-FC05-0.5U | √ | √ | √ | √ | ||||
SM6.6-2GX2S-ST40-0.5U | √ | √ | √ | √ | ||||
SM6.6-2GX2S-SC40-0.5U | √ | √ | √ | √ | ||||
SM6.6-2GX2S-FC40-0.5U | √ | √ | √ | √ | ||||
SM6.6-2GX2S-SC60-0.5U | √ | √ | √ | √ | ||||
SM6.6-2GX2S-SC80-0.5U | √ | √ | √ | √ | ||||
SM6.6-4M-ST05-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-4M-SC05-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-4M-FC05-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-4S-ST40-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-4S-SC40-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-4S-FC40-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-4S-SC60-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-4S-SC80-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-2M2T-ST05-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-2M2T-SC05-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-2M2T-FC05-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-2S2T-ST40-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-2S2T-SC40-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-2S2T-FC40-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-2S2T-SC60-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-2S2T-SC80-0.5U | √ | √ | √ | √ | √ | √ | v | √ |
SM6.6-4T-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
Accessories
Accessory Model | Description |
Gigabit SFP module | See the selection table of industrial gigabit SFP module |
100M SFP module | See the selection table of industrial 100M SFP module |
DT-FCZ-RJ45-01 | Single-port RJ45 dust plug |
DT-XL- Mini USB-USB-2m | 2m USB console cable |
DT-ZJQ-BNC-TNC-01 | BNC(female) to TNC(female) connector |
DT-XL-LMR400-TNC-BNC-20m | 20m coaxial cable with BNC(male) to TNC(male) adaptor |
DT-XL-LMR400-TNC-BNC-2m | 2m coaxial cable with BNC(male) to TNC(male) adaptor |
DT-GPS-ANT-01 | GPS antenna, 5 V DC power supply, 1 TNC connector(female) |
DT-SP-01 | GPS surge protection, TNC connector(male) – TNC connector(female) |